Skip to main content
  • Home
  • Articles
    • Archive from 2022 July
    • Archive 1960 to 2022 June
    • Accepted Articles
    • Published Ahead-of-Print
    • Supplement
  • About
  • For Authors
  • Podcasts

The femur: a good alternative source of bone graft using a new reamer system when options run out

< Back to Listing

Share this Article

Singapore Med J 2013; 54(2): e38-e42; http://dx.doi.org/10.11622/smedj.2013038
The femur: a good alternative source of bone graft using a new reamer system when options run out

  • Abstract
  • PDF
  • References

Wong MK, Low MH, Yong R
Correspondence: Dr Yong Ren, silence_1979sg@yahoo.co.uk

ABSTRACT
Following a post-traumatic incident, orthopaedic surgeons often struggle to look for an abundant source of alternative bone graft because the bone defect is too big or when nonunion is refractory to treatment. We present two cases where the patients’ bone grafts were harvested from the healthy femur. This process involved the use of a new intramedullary reamer, which allowed the bone graft to be harvested simultaneously during the reaming process.

Keywords: bone defect, bone graft, chronic osteomyelitis
Singapore Med J 2013; 54(2): e38–e42; 
 http://dx.doi.org/10.11622/smedj.2013038

http://smj.org.sg/sites/default/files/5402/5402cr5.pdf

REFERENCES

1. Pelissier PH, Martin D, Baudet J, Lepreux S, Masquelet AC. Behavior of cancellous bone graft placed in induced membranes. Br J Plast Surg 2002; 55:596-8.
http://dx.doi.org/10.1054/bjps.2002.3936
 
2. Reamer/Irrigator/Aspirator (RIA) – Synthes. In: Synthes Holding [online]. Available at: http://www.synthes.com/sites/NA/Products/Trauma/IntramedullaryNailingSys.... aspx. Accessed January 29, 2013.
 
3. Nichols TA, Sagi HC, Weber TG, Guiot BH. An alternative source of autograft bone for spinal fusion: the femur: technical case report. Neurosurgery 2008; 62(3 Suppl 1):E179.
http://dx.doi.org/10.1227/01.neu.0000317390.21927.ad
 
4. Hammer TO, Wieling R, Green JM, et al. Effect of re-implanted particles from intramedullary reaming on mechanical properties and callus formation. A laboratory study. J Bone Joint Surg Br 2007; 89:1534-8.
http://dx.doi.org/10.1302/0301-620X.89B11.18994
 
5. Van Gorp CC, Falk JV, Kmiec SJ Jr, Siston RA. The reamer/irrigator/aspirator reduces femoral canal pressure in simulated TKA. Clin Orthop Relat Res 2009; 467:805-9.
http://dx.doi.org/10.1007/s11999-008-0258-8
 
6. Husebye EE, Lyberg T, Madsen JE, Eriksen M, Røise O. The influence of a one-step reamer-irrigator-aspirator technique on the intramedullary pressure in the pig femur. Injury 2006; 37:935-40.
http://dx.doi.org/10.1016/j.injury.2006.06.119
 
7. Higgins TF, Casey V, Bachus K. Cortical heat generation using an irrigating/ aspirating single-pass reaming vs conventional stepwise reaming. J Orthop Trauma 2007; 21:192-7.
http://dx.doi.org/10.1097/BOT.0b013e318038d952
 
×

Around the Site

Home

About SMJ

For Reviewers

Sign Up for Alerts

Issues

Current Issue

All Issues

Online First

Supplement

CME

For Authors

Instructions for Authors

Submit Manuscript


Follow us on:
        

More Links

Contact Us

Copyright

Advertise

SMJ Forms

Privacy Policy

SMA Home

Copyright 2021. Singapore Medical Association. All Rights Reserved.