Skip to main content
  • Home
  • Articles
    • Archive from 2022 July
    • Archive 1960 to 2022 June
    • Accepted Articles
    • Published Ahead-of-Print
    • Supplement
  • About
  • For Authors
  • Podcasts

Wheeze in childhood: is the spacer good enough?

< Back to Listing

Share this Article

Singapore Med J 2014; 55(11): 558-563; http://dx.doi.org/10.11622/smedj.2014150
Wheeze in childhood: is the spacer good enough?

  • Abstract
  • PDF
  • References

Rajkumar V, Rajendra B, How CH, Ang SB
Correspondence: Dr Ang Seng Bin, ang.seng.bin@kkh.com.sg

ABSTRACT
Max was treated with SABA using an MDI and spacer with facemask and responded well to the initial treatment. You explained to the parents that nebulisers are neither required nor recommended in the treatment of wheezing in their child’s situation. You advised the parents on the proper technique of MDI use with spacer and facemask, as well as care of the equipment. You also gave them a clearly written action plan regarding the efficient management of the next episode of wheeze with MDI and spacer. You further explained the side effects of oral bronchodilators and nebulisers, and why you refrained from using them. Max was given a follow-up appointment to assess his progress, and his parents were advised on the situations when they should go to a doctor or the emergency department.

Keywords: asthma, bronchodilator, childhood wheeze, MDI, spacer
Singapore Med J 2014; 55(11): 558-563; http://dx.doi.org/10.11622/smedj.2014150

http://smj.org.sg/sites/default/files/5511/5511practice1.pdf

REFERENCES

1. Tan C, Wong B, Goh DY, Van Bever HP. Monitoring and treatment practices of childhood asthma in Singapore: a questionnaire study. Singapore Med J 2009; 50:54-61.
PMid:19224085
 
2. Chiang WC, Chen YM, Tan HK, et al. Allergic rhinitis and non-allergic rhinitis in children in the tropics: prevalence and risk associations. Pediatr Pulmonol 2012; 47:1026-33.
http://dx.doi.org/10.1002/ppul.22554
 
3. Hess DR. Aerosol delivery devices in the treatment of asthma. Respir Care 2008; 53:699-723; discussion 723-5.
PMid:18501026
 
4. Pedersen S, Dubus JC, Crompton GK, ADMIT Working Group. The ADMIT series – issues in inhalation therapy. 5) Inhaler selection in children with asthma. Prim Care Respir J 2010; 19:209-16.
http://dx.doi.org/10.4104/pcrj.2010.00043
 
5. Konig P. Spacer devices used with metered-dose inhalers. Breakthrough or gimmick? Chest 1985; 88:276-84.
http://dx.doi.org/10.1378/chest.88.2.276
 
6. Appel D. Faulty use of canister nebulizers for asthma. J Fam Pract 1982; 14:1135-8.
PMid:7086365
 
7. Everard ML, Devadason SG, Summers QA, Le Souef PN. Factors affecting total and "respirable" dose delivered by a salbutamol metered dose inhaler. Thorax 1995; 50:746-9.
http://dx.doi.org/10.1136/thx.50.7.746
 
8. Sheth K, Wasserman RL, Lincourt WR, et al. Fluticasone propionate/salmeterol hydrofluoroalkane via metered-dose inhaler with integrated dose counter: Performance and patient satisfaction. Int J Clin Pract 2006; 60:1218-24.
http://dx.doi.org/10.1111/j.1742-1241.2006.01138.x
 
9. Pedersen S, Mortensen S. Use of different inhalation devices in children. Lung 1990; 168 Suppl:653-7.
http://dx.doi.org/10.1007/BF02718190
 
10. Newman SP, Weisz AW, Talaee N, Clarke SW. Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique. Thorax 1991; 46:712-6.
http://dx.doi.org/10.1136/thx.46.10.712
 
11. Newman SP, Woodman G, Clarke SW, Sackner MA. Effect of InspirEase on the deposition of metered-dose aerosols in the human respiratory tract. Chest 1986; 89:551-6.
http://dx.doi.org/10.1378/chest.89.4.551
 
12. Rau JL. Practical problems with aerosol therapy in COPD. Respir Care 2006; 51:158-72.
PMid:16441960
 
13. Clark DJ, Lipworth BJ. Effect of multiple actuations, delayed inhalation and antistatic treatment on the lung bioavailability of salbutamol via a spacer device. Thorax 1996; 51:981-4.
http://dx.doi.org/10.1136/thx.51.10.981
 
14. Mitchell JP, Nagel MW. Valved holding chambers (VHCs) for use with pressurised metered-dose inhalers (pMDIs): a review of causes of inconsistent medication delivery. Prim Care Respir J 2007; 16:207-14.
http://dx.doi.org/10.3132/pcrj.2007.00034
 
15. Smaldone GC, Berg E, Nikander K. Variation in pediatric aerosol delivery: importance of facemask. J Aerosol Med 2005; 18:354-63.
http://dx.doi.org/10.1089/jam.2005.18.354
 
16. Chou KJ, Cunningham SJ, Crain EF. Metered-dose inhalers with spacers vs nebulizers for pediatric asthma. Arch Pediatr Adolesc Med 1995; 149:201?5.
http://dx.doi.org/10.1001/archpedi.1995.02170140083015
 
17. Cates CJ, Welsh EJ, Rowe BH. Holding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma. Cochrane Database Syst Rev 2013; 9:CD000052.
PMid:24037768
 
18. Castro-Rodriguez JA, Rodrigo GJ. Beta-agonists through metered-dose inhaler with valved holding chamber versus nebulizer for acute exacerbation of wheezing or asthma in children under 5 years of age: a systematic review with meta-analysis. J Pediatr 2004; 145:172-7.
http://dx.doi.org/10.1016/j.jpeds.2004.04.007
 
19. Goh AE, Tang JP, Ling H, et al. Efficacy of metered-dose inhalers for children with acute asthma exacerbations. Pediatr Pulmonol 2011; 46:421-7.
PMid:21194171
 
20. Leversha AM, Campanella SG, Aickin RP, Asher MI. Costs and effectiveness of spacer versus nebulizer in young children with moderate and severe acute asthma. J Pediatr 2000; 136:497-502.
http://dx.doi.org/10.1016/S0022-3476(00)90013-1
 
21. Dewar AL, Stewart A, Cogswell JJ, Connett GJ. A randomised controlled trial to assess the relative benefits of large volume spacers and nebulisers to treat acute asthma in hospital. Arch Dis Child 1999; 80:421-3.
http://dx.doi.org/10.1136/adc.80.5.421
 
22. Staggs L, Peek M, Southard G, et al. Evaluating the length of stay and value of time in a pediatric emergency department with two models by comparing two different albuterol delivery systems. J Med Econ 2012; 15:704-11.
http://dx.doi.org/10.3111/13696998.2012.674587
 
23. Ploin D, Chapuis FR, Stamm D, et al. High-dose albuterol by metered-dose inhaler plus a spacer device versus nebulization in preschool children with recurrent wheezing: A double-blind, randomized equivalence trial. Pediatrics 2000; 106(2 Pt 1):311-7.
PMid:10920157
 
24. De Benedictis FM, Selvaggio D. Use of inhaler devices in pediatric asthma. Paediatr Drugs 2003; 5:629-38.
http://dx.doi.org/10.2165/00148581-200305090-00005
 
25. Bowton DL, Goldsmith WM, Haponik EF. Substitution of metered-dose inhalers for hand-held nebulizers. Success and cost savings in a large, acute-care hospital. Chest 1992; 101:305-8.
http://dx.doi.org/10.1378/chest.101.2.305
 
26. Deerojanawong J, Manuyakorn W, Prapphal N, et al. Randomized controlled trial of salbutamol aerosol therapy via metered dose inhaler-spacer vs. jet nebulizer in young children with wheezing. Pediatr Pulmonol 2005; 39:466-72.
http://dx.doi.org/10.1002/ppul.20204
 
27. Rubilar L, Castro-Rodriguez JA, Girardi G. Randomized trial of salbutamol via metered-dose inhaler with spacer versus nebulizer for acute wheezing in children less than 2 years of age. Pediatr Pulmonol 2000; 29:264-9.
http://dx.doi.org/10.1002/(SICI)1099-0496(200004)29:4<264::AID-PPUL5>3.0.CO;2-S
 
28. Direkwatanachai C, Teeratakulpisarn J, Suntornlohanakul S, et al. Comparison of salbutamol efficacy in children – via the metered-dose inhaler (MDI) with Volumatic spacer and via the dry powder inhaler, Easyhaler, with the nebulizer – in mild to moderate asthma exacerbation: a multicenter, randomized study. Asian Pac J Allergy Immunol 2011; 29:25-33.
PMid:21560485
 
29. Delgado A, Chou KJ, Silver EJ, Crain EF. Nebulizers vs metered-dose inhalers with spacers for bronchodilator therapy to treat wheezing in children aged 2 to 24 months in a pediatric emergency department. Arch Pediatr Adolesc Med 2003; 157:76-80.
http://dx.doi.org/10.1001/archpedi.157.1.76
 
30. Giraud V, Roche N. Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability. Eur Respir J 2002; 19:246-51.
http://dx.doi.org/10.1183/09031936.02.00218402
 
31. Iles R, Lister P, Edmunds AT. Crying significantly reduces absorption of aerosolised drug in infants. Arch Dis Child 1999; 81:163-5.
http://dx.doi.org/10.1136/adc.81.2.163
 
32. Amirav I, Newhouse MT. Aerosol therapy with valved holding chambers in young children: importance of the facemask seal. Pediatrics 2001; 108:389-94.
http://dx.doi.org/10.1542/peds.108.2.389
×

Around the Site

Home

About SMJ

For Reviewers

Sign Up for Alerts

Issues

Current Issue

All Issues

Online First

Supplement

CME

For Authors

Instructions for Authors

Submit Manuscript


Follow us on:
        

More Links

Contact Us

Copyright

Advertise

SMJ Forms

Privacy Policy

SMA Home

Copyright 2021. Singapore Medical Association. All Rights Reserved.