A comparison between short-interval and regular-interval follow-up for BI-RADS category 3 lesions

< Back to Listing

Share this Article

Singapore Med J 2010; 51(2): 120-125
A comparison between short-interval and regular-interval follow-up for BI-RADS category 3 lesions

  • Abstract
  • PDF

Ruamsup S, Wiratkapun C, Wibulpolprasert B, Lertsithichai P
Correspondence: Dr Panuwat Lertsithichai, raplt@mahidol.ac.th

ABSTRACT
Introduction
The aim of this study was to compare the short-interval and regular-interval follow-up in women with Breast Imaging Reporting and Data System (BI-RADS) category 3 screen imaging studies. The image stability, rate of image-detected breast cancer and stage of cancer are studied.
Methods Women who had BI-RADS 3 screen imaging studies (mammography and ultrasonography) conducted between the period January 2003 and December 2005 were retrospectively identified using the computerised database at the Department of Radiology, Ramathibodi Hospital, Thailand. Women who had known breast cancer status at two years after screening were included in the study and divided into two groups: short-interval (six months after screening) or regular-interval (one year after screening) follow-up. The two groups were compared in terms of the baseline clinicoradiologic characteristics and outcomes, including the image stability, image-detected breast cancer and the cancer stage at detection.
Results A total of 10,086 women underwent screen imaging studies within the study period. Of these, 1,541 (15 percent) were categorised as BI-RADS 3. Only 1,036 women (67 percent) had follow-up images done six to 12 months after screening, and 846 (82 percent of 1,036 women) also had known cancer status two years after the screening. Breast cancer was noted in seven women (a positive predictive value of 0.7 percent). There were no significant differences between the two groups of women in terms of their baseline characteristics, image stability at the initial follow-up, the rate of image-detected breast cancer and the stage of cancer at detection.
Conclusion There were no significant differences in the effectiveness of short-interval versus regular-interval follow-up in women with BIRADS 3 screen imaging studies.

Keywords: BI-RADS category 3, breast cancer, regular-interval follow-up, screen imaging studies, short-interval follow-up
Singapore Med J 2010; 51(2): 120-125

http://smj.org.sg/sites/default/files/5102/5102a4.pdf
×

Around the Site

Home

About SMJ

For Reviewers

Sign Up for Alerts

Issues

Current Issue

All Issues

Online First

Supplement

CME

For Authors

Instructions for Authors

Submit Manuscript


Follow us on:
        

More Links

Contact Us

Copyright

Advertise

SMJ Forms

Privacy Policy

SMA Home

Copyright 2021. Singapore Medical Association. All Rights Reserved.